Flat Composite Rupture Disc

Burst pressure: 0.02-150barg

Size range: 10mm-1200mm

Operating Range: Can function at ≤50% of rated burst pressure

Advanced Laser-Scoring Technology

No Holder Required

Standard Materials:Cotton-free gaskets/Stainless steel/Fluoropolymer,Custom material options available upon request


Product Details

Product Overview

Flat  composite rupture disc with gasket is evolved from LF rupture disc,mainly used in low pressure application. PF rupture disc can mount between flanges.

Bursting Disc Device

A bursting disc device is a non-reclosing pressure relief component designed to open when exposed to a specified static pressure on its inlet side. It operates by rupturing a pressure-retaining membrane, thereby releasing excess pressure. In simple terms, it is a single-use pressure relief solution: when the preset bursting temperature is reached and the pressure differential across the disc meets the defined limit, the disc will break or detach, allowing the medium to escape.

The design and production of bursting discs must follow applicable safety technical standards. Each unit must be accompanied by a product quality certificate upon delivery, and a durable metal nameplate must be permanently fixed to the product.


Flat Composite Rupture Disc


Options

Rupture Disc Sensor

Holder Assembly

Fluoroplymer Gaskets

Tank Container Rupture Disc

Storage Tank Protection

Storage tanks, typically constructed from lightweight materials with limited pressure capacity, are susceptible to vacuum collapse if not properly vented. PF-type rupture discs offer an economical protection solution.


Flat Composite Rupture Disc


Key Selection Criteria:

Size: ≥ Tank's inlet/outlet diameter (whichever is larger)

Max Burst Pressure: ≤ Tank design pressure/vacuum rating (lower value)

Min Burst Pressure: ≥ 2× Tank operating pressure/vacuum level (higher value)

Relief Valve Protection

Corrosive substances in the atmosphere can enter through safety valve outlets, damaging internal components and

impairing operation. Valves connected to common manifolds are particularly vulnerable. Installing PF-type rupture discs

on the valve outlet flange effectively shields critical components from harsh environments.

Selection Guidelines:

Size: Must match valve outlet flange dimensions

Max Burst Pressure: ≤ Valve set pressure

Min Burst Pressure: ≥ 2× Maximum operating pressure in manifold

Product Parameters

Bursting Pressure Ranges -psig(barg)@72F(22)



Size 

FEP

PTFE 

Aluminum

Nickel 

NPS (in)

DN (mm)

(Psig)

(barg)

(Psig)

(barg)

(Psig)

(barg)

(Psig)

(barg)

min.

max

min.

max

min.

max

min.

max

min.

max

min.

max

min.

max

min.

max

1"

25

11.6

1015

0.8

70

29

1015

2

70

87

1450

6

100

548

1450

24

100

1.25"

32

8.7

870

0.6

60

21.75

870

1.5

60

65.25

1087.5

4.5

75

290

1087.5

20

75

1.5"

40

5.8

725

0.4

50

14.5

725

1

50

52.2

942.5

3.6

65

217.5

942.5

15

65

2"

50

4.35

580

0.3

40

10.88

580

0.75

40

49.3

797.5

3.4

55

203

797.5

14

55

2.5"

65

3.63

522

0.25

36

9.08

522

0.63

36

36.25

725

2.5

50

159.5

725

11

50

3"

80

2.9

464

0.2

32

7.25

464

0.5

32

31.9

580

2.2

40

145

580

10

40

4"

100

2.18

420.5

0.15

29

5.45

420.5

0.38

29

26.1

435

1.8

30

116

435

8

30

5"

125

2.18

377

0.15

26

5.45

377

0.38

26

21.75

435

1.5

30

101.5

435

7

30

6"

150

2.18

333.5

0.15

23

5.45

333.5

0.38

23

18.85

362.5

1.3

25

87

362.5

6

25

8"

200

1.45

340.5

0.1

21

3.63

304.5

0.25

21

14.5

362.5

1

25

72.5

362.5

5

25

10"

250

1.16

24.5

0.08

17

2.9

246.5

0.2

17

11.16

362.5

0.8

25

58

362.5

4

25

12"

300

1.02

203

0.07

14

2.55

203

0.18

14

10.15

290

0.7

20

43.5

290

3

20

14"

350

0.87

174

0.06

12

2.18

174

0.15

12

8.7

290

0.6

20

43.5

290

3

20

16"

400

0.73

145

0.05

10

1.83

145

0.13

10

7.25

232

0.5

16

36.25

232

2.5

16

Max. Temp.

200℃

260℃

400℃

530℃


Size 

Monel

Inconel

Stainless Steel

Hastelloy C-276

NPS (in)

DN (mm)

(Psig)

(barg)

(Psig)

(barg)

(Psig)

(barg)

(Psig)

(barg)

min.

max

min.

max

min.

max

min.

max

min.

max

min.

max

min.

max

min.

max

1"

25

406

1450

28

100

478.5

1450

33

100

406

1450

28

100

435

1450

30

100

1.25"

32

319

1087.5

22

75

377

1087.5

26

75

319

1087.5

22

75

333.5

1087.5

23

75

1.5"

40

261

942.5

18

65

304.5

942.5

21

65

261

942.5

18

65

275.5

942.5

19

65

2"

50

232

797.5

16

55

275.5

797.5

19

55

232

797.5

16

55

261

797.5

18

55

2.5"

65

174

725

12

50

203

725

14

50

174

725

12

50

377

725

26

50

3"

80

159.5

580

11

40

174

580

12

40

159.5

580

11

40

333.5

580

23

40

4"

100

130.5

435

9

30

145

435

10

30

130.5

435

9

30

261

435

18

30

5"

125

116

435

8

30

130.5

435

9

30

116

435

8

30

217.5

435

15

30

6"

150

101.5

362.5

7

25

116

362.5

8

25

101.5

362.5

7

25

203

362.5

14

25

8"

200

87

362.5

6

25

101.5

362.5

7

25

87

362.5

6

25

159.5

362.5

11

25

10"

250

72.5

362.5

5

25

87

362.5

6

25

72.5

362.5

5

25

130.5

362.5

9

25

12"

300

58

290

4

20

72.5

290

5

20

58

290

4

20

116

290

8

20

14"

350

58

290

4

20

72.5

290

5

20

58

290

4

20

101.5

290

7

20

16"

400

43.5

232

3

16

58

232

4

16

43.5

232

3

16

87

232

6

16


FAQ

Q1: What does your company primarily do? Are your qualifications complete?

A1: We specialize in the field of industrial explosion protection and pressure relief safety. Our core products include bursting discs, flame arresters, explosion isolation valves, and flameless venting devices. We hold the "Special Equipment Manufacturing License" (for bursting disc devices) issued by the State Administration for Market Regulation (SAMR). Our products fully comply with national standards like GB/T 567 and TSG ZF003, and we can provide international certifications such as ATEX and PED based on customer requirements.

Q2: How do I select the right equipment for my process conditions?

A2: Accurate selection requires the following key parameters:

Medium: Is it gas, dust, or liquid? What is its specific composition? (e.g., hydrogen, methane, corn starch dust)

Operating Pressure & Temperature: The pressure and temperature range during normal operation.

Design/Burst Pressure & Temperature: The pressure at which the safety device must activate and the temperature of the medium at that moment.

Relief Capacity/Pipe Size: The energy that needs to be vented or the nominal diameter (DN) of the pipeline.

Installation Location & Space: Is it installed indoors/outdoors? At the end of a pipe or on equipment?

Other Requirements: Is corrosion resistance, vacuum support, leak detection, etc., needed?

(Call to Action: Simply provide the above information, and our technical engineers will offer you a free selection service.)


Leave your messages

Related Products

x

Popular products

x
x